OCEMS Compliance

IoT Data Logger for CPCB OCEMS Data Transmission

A CPCB OCEMS data logger collects readings from a plant's emission and effluent analysers and transmits them in real time to the Central and State Pollution Control Board servers. Livwize's IoT data logger sends encrypted, time-stamped data over Ethernet or 4G LTE, buffers it during network outages and retransmits it without loss.

CPCB-Approved, Secure & Real-Time Pollution Monitoring for Indian Industries

India’s Most Trusted CPCB-Compliant OCEMS Connectivity Solution

  • Transmission

    Real-time data push via Ethernet / 4G / LTE

  • Integration

    Works with all CPCB-approved OCEMS analyzers

  • Data Integrity

    Time-stamped, non-editable records

IoT Data Logger for CPCB OCEMS

Overview

OCEMS data acquisition and management system (DAS) for CPCB compliance

Industrial pollution monitoring in India is no longer optional—it is a statutory requirement enforced by the Central Pollution Control Board (CPCB) and respective State Pollution Control Boards (SPCBs). Our IoT Data Logger for CPCB OCEMS Data Transmission is engineered specifically for Indian regulatory frameworks, ensuring accurate, real-time, tamper-proof transmission of emission and effluent data directly to CPCB/SPCB servers. This solution is deployed across power plants, cement units, steel plants, chemical industries, pharmaceuticals, CETPs, STPs, and refineries where compliance, uptime, and audit-readiness are critical.

Base model prices starting from INR 42,500 + GST

Designed Exclusively for CPCB OCEMS Protocols

Built for Indian Industrial Reality

Continuous, Reliable Data Transmission

Capabilities

Core Technical Capabilities

Data Integrity & Cyber Security

Universal Analyzer & Sensor Integration

Compliance-Driven Intelligence

  • End-to-end encrypted data (TLS/SSL)

  • Time-stamped, non-editable records

  • Tamper detection and audit logs

  • Stack monitoring: PM, SO₂, NOx, CO, CO₂, O₂

  • Effluent monitoring: pH, TSS, COD, BOD, Flow

  • Works with all CPCB-approved OCEMS analyzers

  • Threshold-based alerts

  • Automated compliance-ready reports • Supports inspections, audits, and consent renewals

Why Regulators and Auditors Accept This System

CPCB OCEMS Data Transmission Architecture

This architecture ensures zero manipulation, zero gaps, and full regulatory transparency.

Target Markets

Industries Across India Using This Solution

Connect compatible stack and effluent analysers across the following industrial environments.

Thermal Power Plants Cement & Steel Manufacturing Oil & Gas Refineries Chemical & Pharmaceutical Industries Textile & Dyeing Units Common Effluent Treatment Plants (CETP) Sewage Treatment Plants (STP) India-wide support

CPCB OCEMS login and live data: where to find them

The Central Pollution Control Board operates the regulatory portal. Industries use their registered credentials to access their own CPCB OCEMS live data and reporting information. Livwize supplies the logger and connectivity integration; portal account registration and password recovery are handled through CPCB.

For an OCEMS CPCB login or CPCB OCEMS login, use the industry login referenced in CPCB’s connectivity FAQ. If plant data is missing, compare the analyser output, logger status and network connection before contacting support. Share the affected station, parameter and time period with Livwize at connect@livwize.com or +91 7011652015; keep portal passwords private.

For general equipment logging, the remote-monitoring logger connects compatible field instruments to a dashboard.

  1. Check the analyser output, parameter, unit and available interface.
  2. Configure the logger’s channel map, timestamps and reporting interval for the station.
  3. Confirm the station ID issued through the relevant SPCB onboarding process.
  4. Verify network access to the configured CPCB and SPCB reporting destinations.
  5. Compare the first portal readings and timestamps with the logger and analyser output.

OCEMS full form and RTDMS

OCEMS stands for Online Continuous Emission & Effluent Monitoring Systems. CPCB’s published connectivity FAQ expands RTDMS as Real Time Data Management System. It receives online emission and effluent data from connected industries.

An OCEMS data acquisition and management system (DAS) is the logger and software that collect each analyser output, associate it with a timestamp and prepare it for transmission. The system links plant measurements, local records and the configured CPCB or SPCB reporting destination.

How COD and BOD online analysers connect for CPCB OCEMS

COD, BOD, TSS, pH and flow analysers on an effluent line can expose 4–20 mA or Modbus outputs. The logger reads the connected output, maps it to the correct parameter and unit, and transmits the data using the configured reporting interval. The required interval and supported analyser make should be checked against the plant’s approved integration before commissioning.

CPCB OCEMS logger: integration specifications

Select the hardware variant against the analyser interfaces and site environment. The following describes published electrical ratings, storage capacities, operating temperatures, and interface capabilities for this CPCB OCEMS logger.

Use the IoT sensors guide to compare measurement types and interfaces for the installation.

Published OCEMS logger technical specifications and ratings
Specification Published capability & ratings
Analyser integration Stack: PM, SO₂, NOx, CO, CO₂, O₂; effluent: pH, TSS, COD, BOD and flow (4–20 mA, RS-485 Modbus RTU/TCP)
Transmission interfaces Ethernet (10/100 Mbps) / 4G LTE Cat-1 & Cat-4 / Wi-Fi fallback
Regulatory protocol CPCB RTDMS & SPCB JSON/HTTPS protocol; standard 15-min transmission interval
Storage capacity Up to 16 GB micro-SD local flash storage (buffers >180 days of offline telemetry with auto-sync)
Power ratings 9–30 V DC input (12 V / 24 V DC nominal), 15 W maximum power consumption (optional 100–240 V AC, 50/60 Hz adapter)
Operating temperature range −20°C to +70°C operating temperature range; 5% to 95% RH non-condensing
Data integrity & security Timestamped records (NTP sync), TLS 1.2/1.3 encryption, CRC checksums and non-volatile audit logs

Frequently asked questions

Is this IoT data logger CPCB compliant?

It is built to CPCB OCEMS guidelines, uses the prescribed data structure and transmission intervals, and is used for OCEMS data transmission by regulated industries.

Does it work with existing OCEMS analysers?

Yes. It connects to the analysers commonly deployed in India for stack (PM, SO₂, NOx, CO, CO₂, O₂) and effluent (pH, TSS, COD, BOD, flow) monitoring.

What happens if the internet connection drops?

The logger stores readings locally during the outage and retransmits them automatically when the connection returns, so no data is lost.

How much does the CPCB OCEMS data logger cost?

The base model starts at INR 42,500 plus GST. The final price depends on the number of analysers and the connectivity required.

Which industries must install OCEMS in India?

The supplied solution serves regulated sites including thermal power, cement, steel, chemicals and refineries. The applicable monitoring and reporting requirements depend on the site and its regulator directions; discuss the plant and analyser list with the commissioning team.

Which parameters can be connected?

Compatible stack analysers can supply PM, SO₂, NOx, CO, CO₂ and O₂ readings, while effluent instruments can supply pH, TSS, COD, BOD and flow. The connected channels depend on the installed analysers and their available outputs.

Where do I log in to the CPCB OCEMS portal?

CPCB or the relevant State Pollution Control Board manages industry access to its portal. Livwize supplies the data-transmission equipment and does not issue regulator credentials; use the official portal details supplied to your industry.

Ready to Deploy

Ready to Achieve Hassle-Free CPCB OCEMS Compliance?

If you are looking for a reliable, CPCB-ready IoT Data Logger for OCEMS Data Transmission, this solution delivers accuracy, uptime, and regulatory confidence—exactly what Indian regulators and industries demand. Contact us today to schedule a technical discussion, demo, or compliance consultation.